The ClimaWISE offeringScalable Intelligence. Expert Oversight.
ClimaWISE is delivered through a Customer Agreement, combining an intelligence Stage with a Co-Pilot level. The Stage determines your visibility into the installation. The Co-Pilot determines how much ClimaWISE does for you.
StagesOne-time fee
Each Stage expands our visibility into your system. Scale up whenever you are ready.
Stage I
Primary Fingerprint
Full visibility into the primary side. The thermodynamic profile of your chillers typically reveals 5 to 10% in system savings.
Stage II
Primary Optimization
Active optimization with fast ROI. LeakShield AI and dynamic optimization realize up to 25% in total system savings.
Most popularStage III
Full HVAC Fingerprint
Full insight into the interaction between primary and secondary side. Identifies an additional 7 to 12% in system savings.
Stage IV
Full HVAC Optimization
Full synchronization of the entire installation. Up to 35% in total system savings under real maritime conditions.
HVAC-R Co-PilotSubscription
Every Agreement includes a Co-Pilot. The level determines how intensively we are involved, from monitoring to full operational relief.
Standard
Continuous monitoring and alerts. Includes reporting and predefined support hours for your crew. You act, we inform.
Extended
Active optimization partnership. We set shared goals, conduct periodic performance reviews, and provide priority support. We optimize alongside you.
Recommended with Stage IIEnterprise
Full tailored operational relief. Includes newbuild guidance, independent review of quotations and installations, and support during FAT, HAT, and commissioning. We are involved from day one.
Every Stage gives us more visibility. Every Co-Pilot level determines what we do with that visibility for you.
Who we work with
Every vessel type. One platform.
Physics works the same everywhere, but every vessel has a different mission. A superyacht is about guest comfort. A navy vessel prioritises cooling for mission-critical equipment. The ClimaWISE platform understands these differences. We analyse your HVAC-R system's data and adapt to your specific goals at sea.
What we find on every vesselPhysics doesn't lie. Our data proves it.
Decades of hands-on experience taught us that while environments change, the physics remain constant. We translate this field knowledge into actionable data for your HVAC-R system.
01+8–15%
Condenser efficiency mismatch
Seawater pump settings are more conservative than needed. The system works at higher condensing temperatures than necessary. We typically see efficiency gains of 8% to 15% when this is corrected.
02Lifecycle
Compressor short-cycling
Primary and secondary water circuits are often poorly balanced. This causes compressors to start and stop too frequently, leading to unnecessary wear and massive energy waste.
03Hidden
Refrigerant charge off
Subcooling fluctuations indicate refrigerant charge issues across circuits. Because of varying loads, need for refrigerant often stays hidden for months while system efficiency drops silently.
04Coordination
Master and slave mismatch
Chillers often run independently instead of being coordinated by master control. Neither system knows what the other is doing, leading to redundant power draw and unpredictable behavior.
0510 → 95%
Fresh air ratio out of control
Ventilation efficiency frequently fluctuates between 10% and 95% when it should be stable at design. This instability represents a massive hidden energy waste.
06Signal integrity
Sensor deviations
Temperature sensor deviations distort all downstream calculations. The HVAC-R system thinks it is performing well, but the thermodynamic reality is completely different.
These are not exceptions. These are standard findings on vessels that just passed their last service inspection and show zero alarms.
Frequently asked questions
Common questions, straight answers
How can I improve chiller efficiency on board?+
Seawater pump settings are often more conservative than the system's design allows, causing it to run at higher condensing temperatures than necessary. This isn't something to adjust manually on a hunch. ClimaWISE's algorithm is calibrated to the vessel's own design specifications, so it can pinpoint exactly how much margin actually exists before you touch a setting. Whether it's a yacht, cruise ship, or merchant vessel, ClimaWISE typically sees efficiency gains of 8 to 15% once that margin is corrected against the calibrated baseline.
Why does a vessel's chiller compressor keep short-cycling?+
Primary and secondary water circuits are often poorly balanced. This causes compressors to start and stop too frequently, leading to unnecessary wear and massive energy waste. ClimaWISE identifies the root cause through continuous thermodynamic analysis.
How do I detect a refrigerant leak on board before it wastes energy?+
Subcooling fluctuations indicate refrigerant charge issues across circuits. Because of varying loads, refrigerant shortage often stays hidden for months while system efficiency silently drops. ClimaWISE detects charge loss at a 3% deviation, versus 50%+ with traditional monitoring methods.
Why are a ship's chillers consuming more power than they should?+
Chillers often run independently instead of being coordinated by a master controller. Neither system knows what the other is doing, leading to redundant power draw and unpredictable behaviour. ClimaWISE surfaces this coordination gap through continuous performance comparison.
Why is a ship's ventilation system wasting energy?+
Ventilation efficiency regularly fluctuates between 10% and 95% when it should stay stable at the design value. This instability represents significant, hidden energy waste, whether that's guest cabins on a cruise ship or crew quarters on a merchant vessel. ClimaWISE pinpoints the source of the fluctuation through continuous tracking of ventilation efficiency.
Can faulty sensors cause a ship's HVAC system to waste energy?+
Temperature sensor deviations distort all downstream calculations. The HVAC-R system thinks it's performing well, but the thermodynamic reality is completely different. ClimaWISE cross-validates sensor readings against calculated thermodynamic states to catch signal integrity issues.
Let us read your vessel's fingerprint.
Every vessel we connect shows performance drift that went unnoticed. Let us show you what yours looks like and what it is costing you.
Remote survey possible in most cases. No obligation.